McFarlane Aviation Products - AA441CC

Part Number: AA441CC

DRY AIR PUMP

Eligibility Notice

Please verify that this product is eligible for your aircraft before adding it to your cart.

Click here to view product eligibility.
Qty

Free Shipping

Product Details

Tempest Dry Air Vacuum Pumps

Tempest offers a complete line of new and overhauled FAA-PMA approved dry air pumps. 

 

  • Monolithic construction 
  • Wear indicator port 
  • Revolutionary LRT oil drain 
  • Closed front end keeps oil from entering the pump 
  • Radius edges make installation easier 
  • Through bolts maintain constant body torque and alignment
  • Installation gaskets are included with each vacuum pump

 

All new and overhauled Tempest dry air pumps come with patented WIP™ (Wear Indicator Port) that allows for internal observation of the pump’s vanes. The WIP™ helps determine if the pump should be replaced and avoid unscheduled maintenance due to a pump exceeding its life cycle. They also include finned stators for increased cooling and an “ultra-hard” finish on the internal wear surfaces of the stator for low friction and extended life.

 

New Tempest dry air pumps offer a closed coupling area and patented “LRT” diverter. These design features will help you detect and prevent pump contamination from external sources.

 

The 240 and 400 series dry air pumps are rugged, light-weight, and designed with today’s high-performance aircraft in mind. These pumps use a heat-treated, stainless-steel conical pressure plate spring and torsional dampening springs to provide a harmonics-free pressure plate control and smooth temperature compensation. The larger pumps also use hardened stainless-steel pressure plates that are precision ground and lapped to reduce internal leakage and wear. 

 

For these reasons and more, Tempest is the preferred dry air pump of aviation maintenance technicians worldwide.     

 

New Pumps

Each pump is meticulously and professionally hand assembled to insure proper tolerances and clearances. This assures optimum performance. After assembly, each pump is functionally tested. After this initial testing, the pump is disassembled, inspected for any unusual wear or abnormalities, and reassembled for a second test run. This extensivetesting procedure assures that only first-class products leave the facility.

 

Overhauled Pumps

When Tempest receives a core, it is disassembled and all carbon is discarded. Tempest never re-uses carbon. A new stator is used on all 200 series pumps. The larger 400 series pumps have the hard anodize stripped from the center stator and the stator is inspected for cracks. Then the I.D. is reconditioned. After the reconditioning process, each 400 series stator is meticulously inspected for proper dimensions. The stator then receives a new hard anodize coating. All re-used parts are inspected in the overhaul process to make sure that each part meets the FAA-PMA approved requirements process specification 203-6-1009. 

Vacuum Pump Wrench also available. Get into those really tight spots!   

Dry Air Pump Specifications

 

Pump Model Construction Weight Length Diameter Port Size Max Continuous PSI at Pump
200 Series Pumps Short Finned Stator, Fixed End Plate  1.95 lbs 4 3/8" 3.50" 3/8-18 NPT 5.5 PSI
240 Series Pumps Finned Stator, Thermal Compensating Plate 2.45 lbs  4 3/8"  4.06" 3/8-18 NPT 11 PSI
400 Series Pumps Finned Stator, Thermal Compensating Plate 3.20 lbs  5 7/16" 4.06"  1/2-14 NPT 11 PSI

 

Supersedures

Eligibility Notice

Please verify that this product is eligible for your aircraft before adding it to your cart.

Click here to view product eligibility.
OEM Part Number McFarlane Part Number Comment
441CC AA441CC
441CC-17 AA441CC
441CC-3 AA441CC
441CC-9 AA441CC

Eligible Aircraft

Make Series Model Beginning S/N Ending S/N Comment Eligibility Chart
Beechcraft 95 E95 TD-708 TD-9999999 DEICE 1545
Cessna 337 337 337-1490 337-99999 DEICE 1545
Cessna 337 F337G F3370056 F3370084 DEICE 1545
Cessna 337 F337H F3370085 F3379999 DEICE 1545
Cessna 337 FT337GP (FP337) FP3370001 FP3370022 DEICE 1545
Cessna 337 FT337HP (FP337H) FP3370023 FP3379999 DEICE 1545
Cessna 337 P337H P3370293 P3370356 DEICE 1545
Cessna 337 T337B 337-0526 337-0755 DEICE 1545
Cessna 337 T337C 337-0756 337-0978 DEICE 1545
Cessna 337 T337D 337-0979 337-1193 DEICE 1545
Cessna 337 T337E 33701194 33701316 DEICE 1545
Cessna 337 T337F 33701317 33701398 DEICE 1545
Cessna 337 T337G P3370053 P33799999 DEICE 1545
Cessna 421 421C 421C0001 421C1807 DEICE 1545
Cessna 421 421C C1097 421C99999 DUAL INSTRUMENT 1545
Piper PA-31 PA-31-350 31-8052001 31-9999999 LEFT, DEICE 1545
Piper PA-34 PA-34-200 34-7250001 34-7450220 LEFT, DEICE 1545

Frequently Asked Questions

Question
Is an overhauled Dry Air Pump as good as a new pump?
When I start my engine the vacuum gauge reads zero vacuum, but as the engine RPM increases, the gauge will indicate vacuum. What causes this?
What procedures should be taken when replacing a failed pump?
I frequently need to replace my Dry Air Pump. What could be causing this?
Should I use a cooling shroud on my dry air pump?

Related Items

Please verify product details for suitability for your application.

warningWARNING: Cancer and/or Reproductive Harm - www.P65warnings.ca.gov