Select a Category
Free Shipping on orders over $500.00
Lightweight and Extremely Flexible Ducting
Suitable for conveying fumes and air at temperatures ranging from -65°F to +350°F. Not recommended for handling liquids or highly abrasive materials, or for negative pressure applications. Short lengths can be easily joined together to form a continuous length.
SCAT, SCEET, and CEET ducting also available.
Note: CAT part numbers are sold in standard 10-ft lengths, so qty 1 = 10ft of ducting. Part numbers CAT-2 and CAT-2A are sold in 5ft sections, so qty 1 = 5ft of ducting.
Inside Diameter (inches) |
2” |
3” |
4” |
5” |
6” |
7” |
8” |
10” |
12” |
Weight (lbs per foot) |
.15 |
.23 |
.31 |
.39 |
.47 |
.55 |
.63 |
.78 |
.95 |
Inside Bend Radius (inches) |
.50 |
.75 |
1.0 |
1.25 |
1.5 |
1.75 |
2.0 |
2.23 |
2.50 |
Length Required for 180-degree Bend (inches) |
8 |
12 |
16 |
20 |
24 |
28 |
32 |
39 |
46 |
Minimum Burst Pressure (PSIG) |
120 |
105 |
85 |
58 |
44 |
30 |
26 |
16 |
10 |
Internal Working Pressure (PSIG) |
30 |
26 |
21 |
14.5 |
11 |
7.5 |
6.5 |
4 |
2.5 |
Maximum Leakage (cfm/ft at working pressure) |
.030 |
.045 |
.060 |
.075 |
.090 |
.105 |
.120 |
.135 |
.150 |
Crush Resistance (lbs per foot) |
400 |
320 |
290 |
240 |
200 |
190 |
145 |
105 |
60 |
Axial Tensile Strength (lbs) |
425 |
575 |
700 |
900 |
900 |
900 |
900 |
900 |
900 |
Retracted Length (inches) |
3.5 |
3.5 |
3.5 |
2.5 |
2.0 |
2.0 |
2.0 |
2.0 |
2.0 |
Operating Temperature Range |
-65°F to + 350°F |
-65°F to + 350°F |
-65°F to + 350°F |
-65°F to + 350°F |
-65°F to + 350°F |
-65°F to + 350°F |
-65°F to + 350°F |
-65°F to + 350°F |
-65°F to + 350°F |
OUR PARTS ARE ENGINEERED TO LAST LONGER WHILE SOLVING KNOWN SAFETY ISSUES
OVER 40,000 PARTS IN STOCK WITH SAME DAY SHIPPING IF ORDERED BY 3PM
OUR TEAM PROVIDES THE OLD-FASHIONED CUSTOMER SERVICE THAT YOU EXPECT
View our search tips page, support page or please contact us.
Or, try our chat feature, located on the right side of our website during business hours. We welcome your comments and suggestions.